サイクロン分離性能の実験結果

書誌事項

タイトル別名
  • Experimental Results of Separation Performance of Cyclone

この論文をさがす

説明

Separation performance of several small cyclones have been studied experimentally. A cyclone, the diameter of which is about 100mm, can separate submicron particles, because there are less than 10% of particles above 1μm in the downstream flow of the cyclone. A cyclone, the diameter of which is less than 100m, is not useful because there is no further improvement in the separation performance by the reduced diameter, and the clogging of the dust discharge is more liable to occur. A German type cyclone, which has an inverted cone in the dust chamber, also performs well.

収録刊行物

  • 粉体工学会誌

    粉体工学会誌 18 (4), 229-233, 1981

    一般社団法人 粉体工学会