Non-contact Probing for crack detection by using bow-tie antenna
-
- KINUGAWA Yoshiyuki
- Faculty of Engineering, Gunma University
-
- SATO Kazuya
- Faculty of Engineering, Gunma University
-
- MOTOJIMA Kuniyuki
- Faculty of Engineering, Gunma University
-
- MATSUBARA Masaaki
- Faculty of Engineering, Gunma University
Bibliographic Information
- Other Title
-
- ボウタイアンテナを用いた非接触金属探傷法の開発(放送用アンテナ・伝搬技術,一般)
- ボウタイアンテナを用いた非接触金属探傷法の開発
- ボウタイアンテナ オ モチイタ ヒセッショク キンゾク タンショウホウ ノ カイハツ
Search this article
Description
The nondestructive inspection for crack detection in basic and high accuracy is needed for operating nuclear plant facilities in safety. This report presents a new method of non-contact probing for cracks on metallic board by using antenna. In order to verify availability of this method, we performed numerical analysis and experimental measurement of various length of cracks that exist 20mm away from antenna.
Journal
-
- ITE Technical Report
-
ITE Technical Report 35.5 (0), 63-68, 2011
The Institute of Image Information and Television Engineers
- Tweet
Details 詳細情報について
-
- CRID
- 1390001204529076736
-
- NII Article ID
- 110008514232
-
- NII Book ID
- AN1059086X
-
- ISSN
- 24241970
- 13426893
-
- NDL BIB ID
- 11011118
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL Search
- CiNii Articles
-
- Abstract License Flag
- Disallowed