書誌事項
- タイトル別名
-
- PIV Measurement of Inlet and Outlet Flow of High Pressure and High Flow Rate Small-Sized Cooling Fan
- コウアツ ・ コウフウリョウ ナ コガタ レイキャク ファン ノ イリグチ オヨビ デグチ ナガレ ノ PIV ケイソク
この論文をさがす
説明
Data center has been built with spread of cloud computing. Further, electric power consumption of it is growing rapidly. High pressure and high flow rate cooling fans are used for servers in the data center and there is a strong demand to increase pressure and flow rate of it because of increase of quantity of heat from the servers. Contra-rotating rotors have been adopted for some of high pressure and high flow rate cooling fans. It is important to clarify inlet and outlet flows of it by experiments for high performance and stable operation. PIV measurements of a high pressure and high flow rate cooling fan with 40 mm square were conducted and improvements of the flow condition were discussed by the experimental results.
収録刊行物
-
- ターボ機械
-
ターボ機械 43 (2), 108-114, 2015
一般社団法人 ターボ機械協会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390001204545514368
-
- NII論文ID
- 130006301975
-
- NII書誌ID
- AN00004836
-
- ISSN
- 18802338
- 03858839
-
- NDL書誌ID
- 026056811
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- NDL
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可