Analysis of Induced Current Density Inside Human Model which Stands on Conductive Ground Layer in Uniform Electric Field
-
- Chiba Atsuo
- Yonago National College of Technology
-
- Isaka Katsuo
- The University of Tokushima
Search this article
Description
The introduction of extremely low frequency electric fields with human body has become an increasingly important subject since potential health hazards due to the electric fields emitted by extremely high-voltage power lines. The health effect of the weak current induced in the human body as a result of the interaction between human body and power frequency electric fields has been investigated. In this paper, the finite element method is applied to the analysis of the current density distributions in the human model which stands with erect position on the conductive ground layer in the uniform electric field, and the characteristics of such internal current density distributions are clarified.