Measurement and Analysis of AC Loss of NdFeB Sintered Magnet

DOI DOI Web Site Web Site Web Site View 1 Remaining Hide 4 Citations 8 References Open Access

Bibliographic Information

Other Title
  • ネオジム焼結磁石の交流磁気損失の測定並びに解析との比較
  • ネオジム ショウケツ ジシャク ノ コウリュウ ジキ ソンシツ ノ ソクテイ ナラビニ カイセキ ト ノ ヒカク

Search this article

Description

NdFeB sintered magnets are widely used in rotating machines. As the conductivity of NdFeB sintered magnet is fairly high compared with that of ferrite magnet, the eddy current loss due to slot ripple etc. cannot be neglected. If the eddy current loss of permanent magnet becomes large, the temperature of permanent magnet becomes high and the thermal demagnetization becomes serious. Therefore, it is required to evaluate ac loss of permanent magnet. But the measurement of ac loss of permanent magnet under serious operating condition is not reported yet. In this paper, the ac loss of NdFeB sintered magnet was measured using newly developed closed-type measuring equipment. It is shown that the coaxial double coil is useful for accurate measurement of magnetic field. The eddy current loss and hysteresis loss of permanent magnet are obtained by the loss separation. It is illustrated that the hysteresis loss is larger than the eddy current loss in the range of less than several hundred Hertz. The appropriateness of measurement is verified by the numerical analysis.

Journal

Citations (4)*help

See more

References(8)*help

See more

Details 詳細情報について

Report a problem

Back to top