Measurement and Monte Carlo Simulation of Hold-off Characteristics of Pseudo Spark Discharge Gaps
-
- Morokuma Yukihiko
- Keio University
-
- Mochida Yoshihisa
- Keio University
-
- Ono Goji
- Tobu Railway Co. Ltd.
-
- Nakamura Yoshiharu
- Keio University
Bibliographic Information
- Other Title
-
- Measurement and Monte Carlo Simulation
Search this article
Abstract
We measured hold-off voltages in typical pseudo spark discharge gaps for four different working gases: He, Ne, Ar, and N2. The effect of the cathode hole diameter on the hold-off characteristics was also investigated. In order to understand the present observations, a simple Monte Carlo simulation of electron and ion motions in the pseudo spark gap was carried out in He.
Journal
-
- IEEJ Transactions on Fundamentals and Materials
-
IEEJ Transactions on Fundamentals and Materials 116 (11), 993-997, 1996
The Institute of Electrical Engineers of Japan