- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Automatic Translation feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Restraint Method of Voltage Total Harmonic Distortion in Distribution Network by Power Conditioner Systems using Measured Data from IT Switches
-
- Kawasaki Shoji
- Graduate school of Electrical and Electronics Engineering, University of Fukui
-
- Shimoda Kazuki
- Graduate school of Electrical and Electronics Engineering, University of Fukui
-
- Tanaka Motohiro
- Graduate school of Electrical and Electronics Engineering, University of Fukui
-
- Taoka Hisao
- Graduate school of Electrical and Electronics Engineering, University of Fukui
-
- Matsuki Junya
- Graduate school of Electrical and Electronics Engineering, University of Fukui
-
- Hayashi Yasuhiro
- Graduate School of Advanced Science and Engineering, Major in Electrical Engineering and Bioscience, Waseda University
Bibliographic Information
- Other Title
-
- センサ開閉器情報を利用した複数台PCSによる配電ネットワークにおける総合電圧ひずみ率抑制手法
- センサ カイヘイキ ジョウホウ オ リヨウ シタ フクスウダイ PCS ニ ヨル ハイデン ネットワーク ニ オケル ソウゴウ デンアツヒズミ リツ ヨクセイ シュホウ
Search this article
Description
Recently, the amount of distributed generation (DG) such as photovoltaic system and wind power generator system installed in a distribution system has been increasing because of reduction of the effects on the environment. However, the harmonic troubles in the distribution system are apprehended in the background of the increase of connection of DGs through the inverters and the spread of power electronics equipment. In this paper, the authors propose a restraint method of voltage total harmonic distortion (THD) in a whole distribution network by active filter (AF) operation of plural power conditioner systems (PCS). Moreover, the authors propose a determination method of the optimal gain of AF operation so as to minimize the maximum value of voltage THD in the distribution network by the real-time feedback control with measured data from the information technology (IT) switches. In order to verify the validity of the proposed method, the numerical calculations are carried out by using an analytical model of distribution network interconnected DGs with PCS.
Journal
-
- IEEJ Transactions on Power and Energy
-
IEEJ Transactions on Power and Energy 131 (12), 936-944, 2011
The Institute of Electrical Engineers of Japan
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390001204601691520
-
- NII Article ID
- 10030525244
- 210000186786
-
- NII Book ID
- AN10136334
-
- ISSN
- 13488147
- 15206416
- 03854213
- 04247760
-
- NDL BIB ID
- 023349559
-
- Text Lang
- ja
-
- Article Type
- journal article
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- CiNii Articles
- KAKEN
- OpenAIRE
-
- Abstract License Flag
- Disallowed