Self-field Loss in AC Transport Current Loss of MgB2 Superconducting Composites

Bibliographic Information

Other Title
  • MgB2超電導線の交流通電における自己磁界損失
  • MgB2 チョウデンドウセン ノ コウリュウ ツウデン ニ オケル ジコ ジカイ ソンシツ

Search this article

Abstract

The measurement and analysis of AC transport current loss (self-field loss) in MgB2 superconducting composites were studied. In experimental results, the normalized Ic dependency of AC loss in the MgB2 deviated from Norris' theoretical curve. Then a numerical analysis was performed by taking into consideration the model of a round superconducting wire that consisted of three concentric layers. The analysis clearly showed the experimentally obtained results, such as that the phenomenon originated in the inhomogeneity of the critical current density in the wire rod section.