Optimization of the Flow Rate Meter Based on Laser Doppler Anemometer and Evaluation of High Pressure Fuel Injection Rate
-
- Koyama Tetsuji
- 群馬大学
-
- Kawashima Hisanobu
- 群馬大学
-
- Ishima Tsuneaki
- 群馬大学
-
- Obokata Tomio
- 群馬大学
Bibliographic Information
- Other Title
-
- レーザドップラ式流量計の最適化と高圧燃料噴射率評価
- レーザドップラシキ リュウリョウケイ ノ サイテキ カ ト コウアツ ネンリョウ フンシャリツ ヒョウカ
Search this article
Abstract
The authors' group has been developed an LDA flow rate meter for a fuel injection rate measurement. The LDA flow rate meter can realize simultaneous measurements of the fuel injection rate and of the spray characteristics. The various diameters of pipe that is the measuring section of LDA flow meter are tested for improving the measurement accuracy of the high-pressure fuel injection rate. In addition, the oscillation in the flow rate is separated, and the injection rates are re-calculated. It is pointed out that the oscillation is caused by shocks when the injector valve is opening and closing.
Journal
-
- Transactions of Society of Automotive Engineers of Japan
-
Transactions of Society of Automotive Engineers of Japan 44 (2), 299-304, 2013
Society of Automotive Engineers of Japan
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390001204614944512
-
- NII Article ID
- 130006319218
-
- NII Book ID
- AN00105913
-
- ISSN
- 18830811
- 02878321
-
- NDL BIB ID
- 024577324
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL
- CiNii Articles
-
- Abstract License Flag
- Disallowed