Some distinctions of LNG above ground storage tanks and recent developments of construction procedures in countries outside of Japan (mechanical parts)
-
- KONDO Masao
- IHI Corporation
-
- SHIBUYA Kazuyuki
- IHI Corporation
-
- SAKAMOTO Rie
- IHI Corporation
-
- NAKAYAMA Gen
- IHI Corporation
-
- SAITOU Toshiaki
- IHI Corporation
Bibliographic Information
- Other Title
-
- 海外LNGタンクの特徴および最近の建設工事の取り組み (機械関係)
- カイガイ LNG タンク ノ トクチョウ オヨビ サイキン ノ ケンセツ コウジ ノ トリクミ キカイ カンケイ
Search this article
Abstract
As for the LNG above ground storage tanks constructed in countries other than Japan, their mechanical and civil structures are more different than Japanese ones in various points because of the differences in the codes, standards, regional environment and safety criteria. <br>We explain and introduce the approach to the peculiar structure, loading condition and design method (FEM analysis) that have been adopted to the tanks in the other countries by IHI up to now. In addition, a new construction technique and the features are introduced.