Visualization of Vapor Bubbles on Saturation Pool Boiling Heat Transfer from a Horizontal Cylinder. Observation of Nucleate Boiling Regime, Critical Heat Flux Point and Film Boiling Regime.

Bibliographic Information

Other Title
  • 水平円柱の飽和プール沸騰熱伝達における蒸気泡の可視化 核沸騰領域と限界熱流束点および膜沸騰領域の観察
  • スイヘイ エンチュウ ノ ホウワ プール フットウ ネツ デンタツ ニ オケル
  • "Observation of Nucleate Boiling Regime, Critical Heat Flux Point and Film Boiling Regime"
  • 核沸騰領域と限界熱流束点および膜沸騰領域の観察

Search this article

Abstract

Saturation pool boiling heat transfer from a horizontal cylinder to distilled water is studied under an atmospheric pressure condition. The horizontal cylinder is made of platinum. Diameter and length of the cylinder are 0.8mm and 59.7mm, respectively. The horizontal cylinder is heated by a D. C. electric power source. Vapor bubbles on horizontal cylinder are photographed by a flash (25μs) of stroboscope. Vapor bubbles of nucleate boiling regime, critical heat flux point and film boiling regime are visualized.

Journal

References(11)*help

See more

Details 詳細情報について

Report a problem

Back to top