Mass Flowmeter of Pressure Difference Type

DOI

Bibliographic Information

Other Title
  • 差圧式質量流量計

Abstract

The mass fiowmeter of pressure difference type, here reported, resembles Simmonds' mass fiowmeter and the essential difference between them is that the latter has two orifices while the former none. It is found that the theory of Simmonds' mass fiowmeter given by himself is in error, and a correct theory of Simmonds' mass flowmeter is developed in this paper. The mass fiowmeter newly devised is simpler in construction than that by Simmonds. It is experimentally verified that mass flowrate can be obtained by the newly devised mass fiowmeter of pressure difference type.

Journal

  • Oyo Buturi

    Oyo Buturi 37 (4), 334-338, 1968

    The Japan Society of Applied Physics