書誌事項
- タイトル別名
-
- Hybrid GTO Cycloconverter.
- ハイブリッドシキ GTO サイクロコンバータ
この論文をさがす
説明
This paper describes the hybrid cycloconverter in which a self-commutated converter is connected with a line-commutated converter in antiparallel. The conventional cycloconverter has disadvantage of low power factor in power source. However, the hybrid one can achieve unity of displacement factor. The principle of the hybrid cycloconverter is the following:<br>When the phase control angle for a self-commutated converter is controlled on the condition of leading phase, the input power alternately repeats lagging and leading corresponding to the polarity of the output current. In the case of polyphase output, lagging and leading reactive power are canceled each other in power source, and displacement factor becomes unity.<br>Moreover, the output current in hybrid one is continuous with no circulating current. Experiment results obtained from hybrid GTO cycloconverter, in which GTOs are applied to self-turn-off devices, are shown to confirm the theory.
収録刊行物
-
- 電気学会論文誌D(産業応用部門誌)
-
電気学会論文誌D(産業応用部門誌) 112 (9), 807-814, 1992
一般社団法人 電気学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390001204657154688
-
- NII論文ID
- 130000959919
-
- NII書誌ID
- AN10012320
-
- ISSN
- 13488163
- 09136339
-
- NDL書誌ID
- 3782678
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可