Transformer Resonant Phase-Shifted PWM DC-DC Converter for X Ray Power Generator and Its Fuzzy Logic-based Learning Control Scheme
-
- Sun Junming
- Yamaguchi University
-
- Takano Hiroshi
- Hitachi Medical Corporation
-
- Nakaoka Mutsuo
- Yamaguchi University
Bibliographic Information
- Other Title
-
- 医用X線発生用トランス共振形位相シフトPWM DC-DCコンバータとファジィ学習制御
- イヨウ Xセン ハッセイヨウ トランス キョウシンケイ イソウ シフト PWM DC-DC コンバータ ト ファジィ ガクシュウ セイギョ
Search this article
Description
In general, medical-use high-voltage X ray power generator works under a variety of operating conditions of the required output DC voltage and the output current setting values for the X ray tube. A phase-shifted PWM inverter-fed DC-DC power converter with a high-voltage transformer parasitic resonant link which is used for an X ray power generator inherently includes its stiff nonlinear characteristics due to phase-shifted voltage regulation and diode cut off operation in a high-voltage rectifier because of the wide load setting regulation ranges in practical applications. However, superior output voltage response performances of a quick rising time in a transient state and low ripple factor in a steady-state which have to be essentially required for a medical-use X ray power generator could not be sufficiently implemented by various linear modern control approaches because a precise mathematical description with dynamic modeling could not be formulated for wide load variations. For controlling such a nonlinear DC-DC power conversion system, a fuzzy-reasoning-based learning control technique to realize the human capability and much experience to understand the system dynamic and static behavior is more suitable and effective. This paper presents a phase-shifted PWM full bridge inverter type high-voltage DC-DC power converter with a high-voltage transformer parasitic resonant link and its fuzzy-based learning controller, which has excellent dynamic and static behaviors to be utilized in a medical-use X ray power generator operating under conditions of a variety of wide load settings. The effectiveness of feasible fuzzy learning control technique of the DC-DC power converter is discussed and evaluated on the basis of the computer simulation and experimental results in a laboratory set-up. It is proved that the feasible fuzzy-based learning control scheme suitable for this converter is more effective and practical to improve the system output voltage response performances in both the transient and steady states for medical-use X ray power generator. The simulated and experimental results of this converter are actually illustrated in order to substantiate the operating performance validity of the inverter type medical-use X ray power generator operated by the feasible fuzzy-based learning control implementation.
Journal
-
- IEEJ Transactions on Industry Applications
-
IEEJ Transactions on Industry Applications 119 (8-9), 1061-1072, 1999
The Institute of Electrical Engineers of Japan
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390001204657494528
-
- NII Article ID
- 10004297027
- 210000184030
-
- NII Book ID
- AN10012320
-
- ISSN
- 13488163
- 15206416
- 09136339
- 04247760
-
- NDL BIB ID
- 4816626
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed