三相PWMインバータ用ACフィルタインダクタ鉄損の算定

書誌事項

タイトル別名
  • Iron Loss Calculation of AC Filter Inductor for Three Phase PWM Inverters
  • サンソウ PWM インバータヨウ AC フィルタインダクタ テッソン ノ サンテイ

この論文をさがす

抄録

In recent years, remarkable advancement of new power semiconductor devices, such as SiC and GaN, enables the increase of switching frequency of power converters, and hence the volume of passive components, such as AC filters and transformers, can be reduced. However, temperature rise caused by the inductor loss is increasing, and hence iron loss evaluation of the inductor is one of the most important issues to realize high power density converters. Conventionally, an improved generalized Steinmetz equation (iGSE) has proposed in order to calculate the iron loss under a pulse voltage magnetizing condition. However, accurate iron loss calculation of the AC filter inductor used in a PWM inverters cannot be realized. The authors have proposed two methods of iron loss evaluation of AC filter inductors. The first one is a loss map method which can calculate the iron loss without using a real PWM inverter. Another one is an ILA (Inductor Loss Analyzer) which can measure the iron loss in every switching period in a real PWM inverter. In this paper, comparisons of the iron loss between the ILA and the loss map method on both the single-phase and three-phase inverters are studied. It is found that iron loss of the AC filter inductor in the three-phase PWM inverter which is calculated by the loss map method cause a large error on a specific condition. In order to prevent the calculation error, the authors proposed a revised loss map method and proved the effectiveness of the method.

収録刊行物

被引用文献 (3)*注記

もっと見る

参考文献 (11)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ