- MATANO Nobuhisa
- National Research Institute for Metals
-
- ONO Katsumi
- National Research Institute for Metals
-
- FUJII Takayuki
- Mitsubishi Chemical Industries Co., Ltd., Central Research Laboratory
Bibliographic Information
- Other Title
-
- けい光X線分析法によるアルミナ中の酸化ナトリウムの定量
- ケイコウ Xセン ブンセキホウ ニ ヨル アルミナ チュウ ノ サンカ ナトリウム ノ テイリョウ
Search this article
Description
From 0.11 to 0.98% of sodium oxide in alumina as raw material of aluminum was determined by fluorescent X-ray analysis with a standard error of 0.03%.<BR>It was inevitable that only very feeble Na-Kα line was obtained by any standard set of fluorescent X-ray spectrometer, and a reason of this was attributed to a too low transmissivity of the window of the detector for Na-Kα line. A substitution of this by a 1 μ, polypropylene film multiplied sevenfold the measured intensity of Na-Kα line.<BR>Statistical examinations were also carried out on the counting time, the method of counting, the statistical variation of results, etc.
Journal
-
- BUNSEKI KAGAKU
-
BUNSEKI KAGAKU 17 (5), 560-565, 1968
The Japan Society for Analytical Chemistry
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390001204662183936
-
- NII Article ID
- 130000944320
-
- NII Book ID
- AN00222633
-
- NDL BIB ID
- 8442978
-
- ISSN
- 05251931
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed