Vapor Pressure and Saturated Liquid Density of HCFO-1233zd(E) and HCFO-1233xf

  • TANAKA Katsuyuki
    Department of Precision Machinery Engineering, College of Science and Technology, Nihon University

Bibliographic Information

Other Title
  • HCFO-1233zd(E)とHCFO-1233xf の飽和蒸気圧力および飽和液体密度の測定
  • HCFO-1233zd(E)ト HCFO-1233xf ノ ホウワ ジョウキ アツリョク オヨビ ホウワ エキタイ ミツド ノ ソクテイ

Search this article

Description

Vapor pressure and saturated liquid density for HCFO-1233zd(E) and HCFO-1233xf were measured in the temperature range from 300 K to 400 K at intervals of 10 K by the extraction method. Experimental uncertainties are 0.028 K for temperature, 0.4~3.1 kPa for pressure and 0.9~1.4 kg‧m-3 for density. On a basis of the present data, correlations of vapor pressure and saturated liquid density were formulated as a function of temperature. The standard deviations of vapor pressure from correlations were 0.3 kPa for HCFO-1233zd(E) and 0.9 kPa for HCFO-1233xf. The standard deviations of saturated liquid density from correlations were 0.4 kg‧m-3 for HCFO-1233zd(E) and 0.2 kg‧m-3 for HCFO-1233xf.