書誌事項
- タイトル別名
-
- CT-MPR INVALUABLE IN DIAGNOSING ODONTOGENIC MAXILLARY SINUSITIS
この論文をさがす
説明
In everyday examination, it is usual to encounter odontogenic maxillary sinusitis patients. Odontogenic maxillary sinusitis is generally best diagnosed by dental X-ray imaging. Many medical facilities not having a dental X-ray unit use coronal computed tomography (CT) images to diagnose odontogenic maxillary sinusitis. Coronal CT imaging causes artifacts, however due to dental prosthesises. Computed tomography-Multiplanar reformation (CT-MPR) imaging has proved useful in evaluating the paranasal sinus because it is not influenced by dental prosthesises. We evaluated the usefulness of CT-MPR for diagnosing odontogenic maxillary sinusitis by retrospectively analyzing 16 patients, with the following results:<br>1. We coudn't diagnose all cases of odontogenic maxillary sinusitis in posteroanterior and Waters projection images.<br>2. Panoramic radiography is needed to diagnose odontogenic maxillary sinusitis.<br>3. Dental X-ray imaging missed some cases, but all cases were diagnosed by CT-MPR imaging, giving a 100% diagnosestic rate.<br>CT-MPR imaging is thus at least as valuable or better than dental X-ray imaging in diagnosing odontogenic maxillary sinusitis.
収録刊行物
-
- 日本鼻科学会会誌
-
日本鼻科学会会誌 40 (2), 111-115, 2001
日本鼻科学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390001204737956992
-
- NII論文ID
- 130003873728
- 10009522990
-
- NII書誌ID
- AN00062865
-
- ISSN
- 18837077
- 09109153
-
- データソース種別
-
- JaLC
- Crossref
- CiNii Articles
- OpenAIRE
-
- 抄録ライセンスフラグ
- 使用不可