Closure of bronchi in 326 cases was investigated. Only stapling with an automatic stapling device (TA) was performed in 296 cases (90.8%). Hand suturing and/or covering of the bronchial stump were performed in other cases. Hand suturing closure was performed in 12 cases because the bronchial stumps were too short or thick to close with a TA. Additional hand suturing following TA was performed in 7 cases with intraoperative air leakage (2.2% of TA cases) and 4 cases with destroyed bronchial stump. The bronchial stump was covered with a pedicle flap in 11 cases to prevent fistula. Bronchopleural fistulas occurred in 3 cases (1.0% of TA cases). Bronchus closure with a TA is safe, if it can be used appopriately. The bronchial stump should be covered with an intercostal muscular flap in cases at high risk of bronchial fistula.
Journal
-
- The Journal of the Japan Society for Respiratory Endoscopy
-
The Journal of the Japan Society for Respiratory Endoscopy 22 (1), 14-17, 2000
The Japan Society for Respiratory Endoscopy
- Tweet
Details 詳細情報について
-
- CRID
- 1390001204745057536
-
- NII Article ID
- 110002814056
-
- NII Book ID
- AN00357687
-
- ISSN
- 21860149
- 02872137
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- CiNii Articles
-
- Abstract License Flag
- Disallowed