正弦波近似法による振動ピックアップ感度の校正と不確かさの評価および現行法との比較

書誌事項

タイトル別名
  • Calibration of Vibration Pick-up Sensitivity and its Uncertainty Estimation in Sine-approximation Method Compared with the Conventional Methods.
  • セイゲンハ キンジホウ ニヨル シンドウ ピックアップ カンド ノ コウセイ
公開日
1998
DOI
  • 10.2493/jjspe.64.1165
公開者
公益社団法人 精密工学会

この論文をさがす

説明

A newly proposed method in ISO for calibration of vibration pick-up sensitivity is performed and compared with conventional methods experimentally. The proposed method is called sine-approximation method which is described in ISO/CD5347-1. The conventional methods are fringe counting method and minimum point method which are described in IS05347-1. Each method is carried out simultaneously on a same experimental setup using modified Michelson-type interferometer. Signal process procedures for sine-approximation method, such as phase unwrapping and uncertainty in approximation are proposed. A guide for uncertainty estimation in each method is presented. From the experimental results at 10 m/s2 in acceleration, sine-approximation method can be obtained up to 2000 Hz and its expanded uncertainty is estimated as 0.16-0.9 % at coverage factor 2. The main source of uncertainty is voltage measurement of the pick-up output. The new method has advantage on both the operational scope and its uncertainty. Obtained calibration results from each method are agreed within each uncertainty. The experimental results also show that electric and mechanical noise affect to the difference of each result. Those noises lead to inconsistency of calibration results on each method.

収録刊行物

  • 精密工学会誌

    精密工学会誌 64 (8), 1165-1170, 1998

    公益社団法人 精密工学会

被引用文献 (6)*注記

もっと見る

参考文献 (13)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ