High false-positive rate of the Sonotubometry in the diagnosis of the patulous Eustachian tube

  • Kikuchi Toshiaki
    Department of Otolaryngology-Head and Neck Surgery, Tohoku University school of Medicine
  • Kobayashi Toshimitsu
    Department of Otolaryngology-Head and Neck Surgery, Tohoku University school of Medicine
  • Oshima Takeshi
    Department of Otolaryngology-Head and Neck Surgery, Tohoku University school of Medicine
  • Takata Iori
    Department of Otolaryngology-Head and Neck Surgery, Tohoku University school of Medicine
  • Oshima Hidetoshi
    Department of Otolaryngology-Head and Neck Surgery, Tohoku University school of Medicine
  • Ikeda Ryokichi
    Department of Otolaryngology-Head and Neck Surgery, Tohoku University school of Medicine
  • Kawase Tetsuaki
    Department of Otolaryngology-Head and Neck Surgery, Tohoku University school of Medicine Laboratory of Rehabilitative Auditory Science, Tohoku University Graduate School of Biomedical Engineering

Bibliographic Information

Other Title
  • 耳管開放症診断における音響耳管法(sonotubometry)の問題点
  • ─高い偽陽性率と検査法の位置づけ─

Search this article

Description

Sonotubometry is used in diagnosis of the patulous Eustachian tube (PET).<br>When using the apparatus, either one of the following parameters is used as a positive sign for the PET, i.e., the extension of the duration of ET opening upon swallowing and the decrease in the test tone sound pressure level applied to the nostril. However, these parameters are known to include considerable rates of false-positive and cut-off values for these parameters in diagnosing the PET are not yet standardized. In this report, we performed sonotubometry in 102 ears of 51 cases with unilateral sensorineural hearing loss (SNHL) without PET, in order to evaluate the specificity of sonotubometry in the diagnosis of the PET.<br>Either ‘the extension of the duration of ET opening upon swallowing’ or ‘the decrease in the test tone sound pressure level applied to the nostril’ was found in 66.7% of the SNHL cases without PET, showing the low specificity of these parameters in the diagnosis of the PET. On the other hand, one distinct pattern of sonotubometry recording (plateau type), representing continuous opening of the ET after swallowing, was never found in SNHL cases without PET, and therefore thought to be specific for PET.

Journal

  • Otology Japan

    Otology Japan 23 (3), 193-197, 2013

    Japan Otological Society

References(5)*help

See more

Details 詳細情報について

Report a problem

Back to top