INFLUENCE OF VENTILATION ROUTES UPON FORMALDEHYDE CONCENTRATION IN HOUSES
-
- YAMADA Hiromi
- Institute of Building Science, Sekisui House Ltd.
-
- TANABE Shin-ichi
- Department of Architecture, Waseda University
-
- HAYASHI Motoya
- Miyagi Gakuin Women's College
Bibliographic Information
- Other Title
-
- 換気経路によるホルムアルデヒド気中濃度への影響
- カンキ ケイロ ニ ヨル ホルムアルデヒドキチュウ ノウド エ ノ エイキョウ
Search this article
Description
This paper aims at clarifying the influence that the ventilation characteristics have on formaldehyde concentration in a house. The indoor formaldehyde concentration, ventilation rates and routes have been measured using an experimental house. The formaldehyde concentration has been calculated by characteristics of emission rates. It was found that the room in which polluted air flows is higher than that of an inflow of outdoor air. It is important to design ventilation routes into which polluted air doesn't flow. The calculated concentration is consistent with the measurement results excluding the period after being made airtight. After being sealed, the experiment value decreased gently as compared with the calculation value.
Journal
-
- Journal of Architecture and Planning (Transactions of AIJ)
-
Journal of Architecture and Planning (Transactions of AIJ) 67 (559), 21-27, 2002
Architectural Institute of Japan
- Tweet
Details 詳細情報について
-
- CRID
- 1390001204780944384
-
- NII Article ID
- 110004081785
-
- NII Book ID
- AN10438548
-
- ISSN
- 18818161
- 13404210
-
- NDL BIB ID
- 6322518
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed