FILED INVESTIGATION ON AIR TEMPERATURE DISTRIBUTION INSIDE AN ENCLOSED ARCADE LOCATED IN THE AREA WITH MILD AND SUNNY CLIMATE

  • TSUJIHARA Makihiko
    Dept. of Global Environment Engineering, Graduate School of Engineering, Kyoto University
  • NAKAMURA Yasuto
    Dept. of Global Environment Engineering, Graduate School of Engineering, Kyoto University
  • TANAKA Minoru
    Kamimura Iron Works Co. Ltd.
  • OHTSUKA Junki
    Dept. of Global Environment Engineering, Graduate School of Engineering, Kyoto University

Bibliographic Information

Other Title
  • 温暖多照地域における全蓋型アーケード内部の気温分布性状
  • オンダン タショウ チイキ ニ オケル ゼンガイガタ アーケード ナイブ ノ

Search this article

Abstract

Air temperature distribution inside an enclosed arcade located in the area with mild and sunny climate was investigated on field observations both in summer 1995 and in winter 1996. Air temperature at the height of 0.5 meter in the occupied zone was a little higher than outside air temperature excluding the daytime to the evening in summer. Vertical distribution of air temperature showed a slope of high temperature in the upper part and low temperature in the lower part, in which the degree of the gradient was proportional to the amount of solar radiation and the magnitude depended on the rate of ventilation.