書誌事項
- タイトル別名
-
- Safety and effectiveness of 5-fluorouracil loaded microsphere for classical hepatocellular carcinoma
- コテンテキ カン サイボウ ガン ニ タイスル 5-fluorouracil ガンシン マイクロスフィア ノ アンゼンセイ ・ ユウコウセイ
この論文をさがす
抄録
Aim: We assessed the safety and effectiveness of drug-eluting beads transarterial chemoembolization (DEB TACE) with 5-fluorouracil (5FU) loaded HepaSphere for classical hepatocellular carcinoma (HCC). Regimen: A: 5FU 250 mg/5 ml, non-ionic contrast medium (CM) 5 ml, HepaSphere 25 mg, B: 5FU 400 mg/8 ml, CM 2 ml, HepaSphere 25 mg, C: 5FU 300 mg/6 ml, CM 2 ml, 10% NaCl 2 ml, HepaSphere 25 mg, D: The regimen C is diluted from 10 times. Results: There was no CTCAE Grade 2-5 adverse reaction. The response (CR/PR/SD/PD, CR+PR rate) was as follows; A; 0/1/3/0, 25%, B; 0/1/5/0, 16.7%, C; 1/1/2/0, 50%, D; 1/2/3/0, 50%. Conclusion: DEB TACE with 5FU loaded HepaSphere for classical HCC is safe. It seems to be more favorable with well-tolerated and effective method uses 10% NaCl.
収録刊行物
-
- 肝臓
-
肝臓 57 (4), 190-192, 2016
一般社団法人 日本肝臓学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390001204793189504
-
- NII論文ID
- 130005149505
-
- NII書誌ID
- AN00047770
-
- ISSN
- 18813593
- 04514203
-
- NDL書誌ID
- 027257040
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可