オルセイン染色の実態調査結果と標準化への試み

  • 角田 優子
    金沢大学大学院医学系研究科形態機能病理学
  • 斉川 邦和
    金沢大学大学院医学系研究科形態機能病理学
  • 松下 信之
    金沢大学大学院医学系研究科形態機能病理学
  • 原田 憲一
    金沢大学大学院医学系研究科形態機能病理学
  • 中沼 安二
    金沢大学大学院医学系研究科形態機能病理学

書誌事項

タイトル別名
  • Standardized protocol of orcein staining based on survey of technical procedures in different institutions
  • オルセイン センショク ノ ジッタイ チョウサ ケッカ ト ヒョウジュンカ エ ノ ココロミ

この論文をさがす

抄録

Copper deposition of periportal hepatocytes indicates chronic cholestasis and it is regarded as a very important histological finding to diagnose primary biliary cirrhosis (PBC) and define its stage. Orcein stain makes copper-binding protein visible clearly and sensitively. However, there are variations in orcein staining results every institutions. In order to generalize and standardize staining method, we surveyed the methods of orcein stain at 11 institutions including our laboratory. Consequently, there were differences in staining result according to the kinds of orcein reagents and reducers. As for staining of copper-binding protein, combination of orcein reagent manufactured by Merck or Tokyo Chemical Industry and 1.5 to 3%oxalic acid as reducer is recommended.

収録刊行物

  • 肝臓

    肝臓 54 (10), 716-719, 2013

    一般社団法人 日本肝臓学会

参考文献 (4)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ