Clinical trial of percutaneous radio frequency ablation therapy by two-step insertion method using VirtuTRAX<sup>TM</sup> instrument navigator
-
- Kuzuya Teiji
- Department of Gastroenterology and Hepatology, Nagoya University of Medicine
-
- Ishizu Yoji
- Department of Gastroenterology and Hepatology, Nagoya University of Medicine
-
- Niinomi Takurou
- Department of Gastroenterology and Hepatology, Nagoya University of Medicine
-
- Imai Norihiro
- Department of Gastroenterology and Hepatology, Nagoya University of Medicine
-
- Achiwa Kouichi
- Department of Gastroenterology and Hepatology, Nagoya University of Medicine
-
- Arakawa Takahiro
- Department of Gastroenterology and Hepatology, Nagoya University of Medicine
-
- Yamada Keiichi
- Department of Gastroenterology and Hepatology, Nagoya University of Medicine
-
- Nakano Satoshi
- Department of Gastroenterology and Hepatology, Nagoya University of Medicine
-
- Honda Takashi
- Department of Gastroenterology and Hepatology, Nagoya University of Medicine
-
- Hayashi Kazuhiko
- Department of Gastroenterology and Hepatology, Nagoya University of Medicine
-
- Ishigami Masatoshi
- Department of Gastroenterology and Hepatology, Nagoya University of Medicine
-
- Ishikawa Tetsuya
- Department of Gastroenterology and Hepatology, Nagoya University of Medicine
-
- Nakano Isao
- Department of Gastroenterology and Hepatology, Nagoya University of Medicine
-
- Katano Yoshiaki
- Department of Gastroenterology and Hepatology, Nagoya University of Medicine
-
- Itoh Akihiro
- Department of Gastroenterology and Hepatology, Nagoya University of Medicine
-
- Hirooka Yoshiki
- Department of Gastroenterology and Hepatology, Nagoya University of Medicine
-
- Izumi Namiki
- Division of Gastroenterology and Hepatology, Musashino Red Cross Hospital
-
- Goto Hidemi
- Department of Gastroenterology and Hepatology, Nagoya University of Medicine
Bibliographic Information
- Other Title
-
- 穿刺治療支援アプリケーションVirtuTRAX<sup>TM</sup>を用いた2ステップ法によるラジオ波焼灼術の試み
- 穿刺治療支援アプリケーションVirtuTRAXを用いた2ステップ法によるラジオ波焼灼術の試み
- センシ チリョウ シエン アプリケーション VirtuTRAX オ モチイタ 2 ステップホウ ニ ヨル ラジオハ ショウシャクジュツ ノ ココロミ
- Clinical trial of percutaneous radio frequency ablation therapy by two-step insertion method using VirtuTRAXTM instrument navigator
Search this article
Abstract
We performed percutaneous radio frequency ablation (RFA) therapy by two-step insertion method using VirtuTRAXTM (GE Healthcare, USA) instrument navigator. Subjects were 16 patients (23 nodules) with hepatocellular carcinoma. VirtuTRAXTM position sensor was attached to the hilt of 14-gauge outer needle. In all cases, we could perform 17- gauge Cool-tip RFA without the positional gap between the virtual tract and the actual needle which was caused by the deflection of the needle. The reasons without causing the positional gap were that the outer needle was more rigid than Cool-tip needle, and that it was inserted using initial insertion of a 21-gauge guided needle. RFA by two-step insertion method using VirtuTRAXTM is suggested to be more safe and effective than conventional RFA.
Journal
-
- Kanzo
-
Kanzo 54 (12), 850-853, 2013
The Japan Society of Hepatology
- Tweet
Details 詳細情報について
-
- CRID
- 1390001204795336448
-
- NII Article ID
- 130003384496
-
- NII Book ID
- AN00047770
-
- ISSN
- 18813593
- 04514203
-
- NDL BIB ID
- 025115532
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed