真空露光装置でのステージ温調機構の開発

書誌事項

タイトル別名
  • Development of Stage Temperature Control for Vacuum Lithography Tool
  • シンクウ ロコウ ソウチ デ ノ ステージオンチョウキコウ ノ カイハツ フタツ ノ コウセイノウオンチョウアプローチ
  • —Two approaches of fine temperature control—
  • —2つの高性能温調アプローチ—

この論文をさがす

抄録

It has become a recent trend to apply a special environment into a lithography tool, for instance, immersion, EPL (Electron beam Projection Lithography) and EUVL (Extreme Ultra Violet Lithography) in order to exposure less than 22nm line and space at semiconductor industry field. For a cooling system that a heater is surrounded by metal can and a coolant is supplied into the can by using movable tubes, not only flexibility, damping, durability, particle protection and anti-liquid, etc, but also pressure-resistance, low outgasing and low leak from connections, etc might be strongly taken into account for vacuum lithography. Especially, because a coolant leak is very critical for EUVL in which a partial pressure of several molecular is strictly restricted, a special tube and joint have to be required in the case of liquid cooling system. On the other hand, a gas cooling can be one candidate because of a lower leak damage, however it is necessary to compensate its low cooling efficiency of gas system by using temperature feedback control. In this paper, two guide lines of a cooling mechanism for wafer and mask stage of vacuum compatible tool, a liquid cooling and gas cooling system are introduced.

収録刊行物

  • 精密工学会誌

    精密工学会誌 76 (7), 797-803, 2010

    公益社団法人 精密工学会

被引用文献 (1)*注記

もっと見る

参考文献 (1)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘