ROBOT-ASSISTED LAPAROSCOPIC PARTIAL NEPHRECTOMY USING daVinci S<sup>TM</sup> -SURGICAL SYSTEM FOR LOCALIZED RENAL TUMOR: REPORT OF INITIAL FIVE CASES

Bibliographic Information

Other Title
  • 限局性腎腫瘍に対するdaVinci<sup>TM</sup> Sシステムを用いたロボット支援腹腔鏡下腎部分切除術(RALPN)~初期5症例の治療成績の検討~
  • 限局性腎腫瘍に対するdaVinci Sシステムを用いたロボット支援腹腔鏡下腎部分切除術(RALPN)--初期5症例の治療成績の検討
  • ゲンキョクセイジンシュヨウ ニ タイスル daVinci S システム オ モチイタ ロボット シエン フククウキョウ カジンブブン セツジョジュツ RALPN ショキ 5 ショウレイ ノ チリョウ セイセキ ノ ケントウ

Search this article

Abstract

(Objectives) For the management of patients with small renal tumor, laparoscopic partial nephrectomy (LPN) provides similar oncological control as radical nephrectomy (RN) and is superior to RN with respect to preserving renal function and preventing chronic kidney disease (CKD). The challenge of LPN is to resect a tumor in a bloodless field within a limited warm ischemia time (WIT), followed by hemostatic renorrhaphy under restricted movement of laparoscopic forceps. Therefore, LPN still remains challenging to even experienced laparoscopic surgeon. DaVinci device improved the movability of forceps in LPN and provided three-dimensional visualization. We evaluated outcome and safety of our first series of robot-assisted laparoscopic partial nephrectomy (RALPN) for localized kidney tumor. There was no previous report of RALPN undertaken in our country.<br> (Patients and methods) Since August 2010, our team carried out RALPN for a total of five cases of renal tumor. There were four males and one female with an age range of 41 to 65 years-old. Size of tumor ranged from 15 to 28mm, located in exophytic region, and four cases in right side and one in left. RALPN was undertaken by single surgeon through transperitoneal approach in two cases and retroperitoneal in tree.<br> (Results) RALPN was completed in all patients without conversion to open or hand-assisted surgery. The median operative time and the estimated blood loss were 189 minutes, ranged from 150 to 264, and 29ml, from 10 to 50, respectively. The median volume of removed tumor and the length of WIT were 7g, ranged from 4 to 13g, and 18 minutes, from 13 to 26 minutes, respectively. No complications or reoperations were associated during or post our RALPN cases. Pathological examination of removed tumor showed renal cell carcinoma with negative surgical margin in all cases.<br> (Conclusions) Introduction of daVinciTM device to LPN made this procedure, RALPN, a secured and promising one, which leading to shorten the WIT and to achieve satisfied renorrhaphy. Even for the complex and technically challenging renal tumors, robotic assistance is expected to provide patients the benefit of minimally invasive surgery with safety and satisfactory renal function.<br>

Journal

References(45)*help

See more

Details 詳細情報について

Report a problem

Back to top