Development and Validation of an Analytical Method for Bromate by Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS)
-
- KOBAYASHI Norihiro
- Division of Environmental Chemistry, National Institute of Health Sciences
-
- KOSAKA Koji
- Department of Environmental Health, National Institute of Public Health Present Affiliation: Graduate School of Engineering, Kyoto University
-
- ASAMI Mari
- Department of Environmental Health, National Institute of Public Health
-
- NAKAGAWA Shinya
- Tokyo Metropolitan Institute of Public Health
-
- KINOSHITA Teruaki
- Tokyo Metropolitan Institute of Public Health
-
- TAKAGI Sokichi
- Osaka Institute of Public Health
-
- NAKAJIMA Takae
- Osaka Institute of Public Health
-
- FURUKAWA Koji
- Mie Prefecture Environmental Conservation Agency
-
- NAKAMURA Hiroki
- Gifu Research Center for Public Health
-
- KUDO Kiyonobu
- The Laboratory of Iwate Pharmaceutical Association
-
- KASUYA Tomohiro
- Chiba Pharmaceutical Association
-
- TSUCHIYA Kaori
- Bureau of Waterworks, Tokyo Metropolitan Government
-
- TERANAKA Ikuo
- Saitama Prefectural Water Quality Management Center
-
- WAKATSUKI Kiyoko
- Fukuoka District Waterworks Agency
-
- KADO Yuki
- Waterworks Bureau, City of Hiroshima
-
- KOSEKI Eiichirou
- Sendai City Waterworks Bureau
-
- INOUE Satoshi
- Yokohama Waterworks Bureau
-
- MURAKAMI Shinichi
- Waterworks Bureau, City of Fukuyama
-
- KANETA Satoru
- Hachinohe Regional Water Supply Authority
-
- SEKI Keiko
- Chiba Prefectural Waterworks Bureau
-
- KITAMOTO Yasuko
- Water Examination Laboratory of Osaka Municipal Waterworks Bureau
-
- HORIIKE Hideki
- Shimadzu Corporation
-
- YONEKUBO Jun
- Nihon Waters K.K.
-
- SHIMIZU Naoto
- Agilent Technologies Japan, Ltd.
-
- TAKAHARA Reika
- GL Sciences Inc.
-
- SAITO Kaori
- Thermo Fisher Scientific K.K.
-
- IKARASHI Yoshiaki
- Division of Environmental Chemistry, National Institute of Health Sciences
Bibliographic Information
- Other Title
-
- 液体クロマトグラフィータンデム質量分析による水道水中の臭素酸イオン分析条件の検討と妥当性評価
- エキタイ クロマトグラフィータンデム シツリョウ ブンセキ ニ ヨル スイドウ スイチュウ ノ シュウソサン イオン ブンセキ ジョウケン ノ ケントウ ト ダトウセイ ヒョウカ
Search this article
Description
We developed a liquid chromatography–tandem mass spectrometry (LC/MS/MS) analysis method for the determination of bromate in drinking water. Furthermore, we have conducted a validation test along with 23 organizations to confirm the validity of the analytical method. Recovery tests of bromate spiked into drinking water obtained by each organization were performed with two set points, that is the standard value (0.01 mg L-1) and 1/10 of the standard value (0.001 mg L-1) of bromate in the Japanese Waterworks Act. The linearity of calibration curves, selectivity, accuracy (recovery) , repeatability, and intermediate precision of bromate concentrations were calculated by the data of the recovery tests. The linearity of the calibration curves and selectivity were satisfactory. The accuracy, repeatability, and intermediate precision for the two concentrations obtained by the recovery tests satisfied the criteria in the guideline for the validation of the testing method for drinking water. These criteria are provided by the Ministry of Health, Labour and Welfare, Japan. Therefore, we concluded that the analytical method developed in the present study is valid for the analysis of bromate in drinking water.
Journal
-
- Journal of Japan Society on Water Environment
-
Journal of Japan Society on Water Environment 40 (6), 223-233, 2017
Japan Society on Water Environment
- Tweet
Details 詳細情報について
-
- CRID
- 1390001205081793792
-
- NII Article ID
- 130006199367
-
- NII Book ID
- AN10372439
-
- ISSN
- 18813690
- 09168958
-
- NDL BIB ID
- 028729472
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed