Filtration Performance of Dust Respirators Against Nanoparticles
-
- MYOJO Toshihiko
- Department of Environmental Health Engineering, Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health
-
- OYABU Takako
- Department of Environmental Health Engineering, Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health
-
- OGAMI Akira
- Department of Occupational Pneumology, Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health
-
- MORIMOTO Yasuo
- Department of Occupational Pneumology, Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health
-
- NISHI Kenichiro
- Department of Environmental Health Engineering, Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health
-
- KADOYA Chikara
- Department of Environmental Health Engineering, Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health
-
- YAMAMOTO Makoto
- Department of Environmental Health Engineering, Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health
-
- TODOROKI Motoi
- Department of Occupational Pneumology, Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health
-
- MIZUGUCHI Yohei
- Department of Environmental Health Engineering, Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health
-
- LEE Byeong Woo
- Department of Environmental Health Engineering, Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health
-
- HASHIBA Masayoshi
- Department of Occupational Pneumology, Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health
-
- KAMBARA Tatsunori
- Department of Occupational Pneumology, Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health
Bibliographic Information
- Other Title
-
- 防じんマスクのナノ粒子に対する捕集性能
- ボウジンマスク ノ ナノ リュウシ ニ タイスル ホシュウ セイノウ
Search this article
Description
It is necessary to consider protective measures, such as dust respirators, against the inhalation of nanoparticle aerosols. Industrial hygienists and workers handling nanomaterials are concerned about the filteration performance of dust respirators in protecting against nanoparticles, the size of which is less than 100nm. We developed a filteration performance evaluating system using titanium dioxide nanoparticle aerosols ranging from 15 to 220nm in diameter. The system, which includes two models of DS1 class and four models of DS2 class, was used to measure the collection efficiencies of dust respirators. These tested dust respirators had been certified by the Japanese government. In the dust respirators, there were no samples that showed less collection efficiency than the standard certified collection efficiency (80% for DS1 and 95% for DS2).
Journal
-
- Journal of UOEH
-
Journal of UOEH 33 (2), 163-171, 2011
University of Occupational and Environmental Health, Japan
- Tweet
Details 詳細情報について
-
- CRID
- 1390001205084149504
-
- NII Article ID
- 110008670941
-
- NII Book ID
- AN0009832X
-
- ISSN
- 21872864
- 0387821X
-
- NDL BIB ID
- 11143188
-
- PubMed
- 21702121
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed