書誌事項
- タイトル別名
-
- Increasing Precision of Pupil Position Detection Using the Corneal Reflection
- カクマク ハンシャ オ リヨウシタ ドウコウ イチ ケンシュツ ノ コウセイドカ
この論文をさがす
説明
In general, the relative position between the centers of the pupil and corneal reflection are used for precise eye-gaze detection. Recently, for stable pupil detection under various ambient light conditions, the pupil has been detected by the difference between the bright and dark pupil images. However, due to the difference in acquisition timing between the bright and dark images, the precision of the pupil position easily decreases when the head moves. We propose a compensation method which differentiates those pupil images after shifting one of the images so that the positions of corneal reflections in both images should match, and show its effectiveness.
収録刊行物
-
- 映像情報メディア学会誌
-
映像情報メディア学会誌 62 (7), 1122-1126, 2008
一般社団法人 映像情報メディア学会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390001205097116288
-
- NII論文ID
- 110006794854
-
- NII書誌ID
- AN10588970
-
- ISSN
- 18816908
- 13426907
-
- NDL書誌ID
- 9562585
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- NDLサーチ
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可