Continuous Measurement of Inner Temperatures of Slab Travelling through Continuously Reheating Furnace
-
- OTAKI Hiroshi
- 日本鋼管株式会社鶴見製鉄所
-
- SASAKA Saburo
- 日本鋼管株式会社鶴見製鉄所
-
- FUJII Taiji
- 日本鋼管株式会社鶴見製鉄所
-
- TOYOTA Hiromichi
- 日本鋼管株式会社鶴見製鉄所
Bibliographic Information
- Other Title
-
- 連続加熱炉における鋼塊の内部温度測定
Description
An experimental test for continuously measuring inner temperatures of a slab passing through a continuously reheating furnace was carried out to improve heating operations. A test slab was drilled two holes on its side and then charged into the furnace, together with two CA thermocouples (2.3mmφ) which were protected with porcelain insulators, threefold asbestos tapes and "Brick Coat", and were fixed in the two holes. The inner temperatures of the two holes were continuously recorded by an electronic potentiometer during the slab was heated by the furnace. As a result, it was confirmed that these couples can be useful for more than three hours even at the temperature exceeding 1200°C. Calibration proved that the E.M.F. of the couples were not changed after the above heating operation.
Journal
-
- Journal of the Instrument Technology, Japan
-
Journal of the Instrument Technology, Japan 6 (7), 336-339, 1956
THE SOCIETY OF INSTRUMENT AND CONTROL ENGINEERS
- Tweet
Details 詳細情報について
-
- CRID
- 1390001205121652480
-
- NII Article ID
- 130003935462
-
- ISSN
- 18838154
- 04500024
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- CiNii Articles
-
- Abstract License Flag
- Disallowed