書誌事項
- タイトル別名
-
- Fatigue Strength and Size Effect of Shrink-fitted Specimens
- ヤキバメジク ノ ツカレ ツヨサ ト スンポウ コウカ
この論文をさがす
抄録
This paper deals with the summary of the results of rotating-bending fatigue tests on shafts 10 to 100 mm in diameter of medium carbon steel of 0.39% carbon content. Shafts were tested under a concentrated stress, as represented by both shrink-fitted member and fillet. Shrink-fitted specimen hardened by induction-hardening exhibited large size effect as well as untreated shrink-fitted specimen ; the reudction ratio 1.8 was obtained by comparing the endurance limit for shrink-fitted specimen 10 mm in diameter with that of the 100 mm in diameter and the value 1.6 was obtained for induction-hardened shrink-fitted specimens. The enduramce limit of large shrink-fitted specimen as well as small one was increased by 1.8∼2.1 times by induction-hardening. The stress distribution of shrink-fitted specimens with fillet was studied by the photo-elastic method and was investigated the critical ratio between the diameters of fillet specimen, in which the stress at the end of shrink-fitted part is equal to that of fillet part. By using this critical ratio between the diameters was given a practical expedience for increasing the fatigue strength of shrink-fitted specimen with fillet.
収録刊行物
-
- 日本機械学會論文集
-
日本機械学會論文集 28 (185), 29-38, 1962
一般社団法人 日本機械学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390001205155208960
-
- NII論文ID
- 110002351564
-
- NII書誌ID
- AN00187419
-
- ISSN
- 21859485
- 00290270
-
- NDL書誌ID
- 9150902
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可