Construction of Simple Dynamic Model for OTEC Plant Using Rankine Cycle

Bibliographic Information

Other Title
  • ランキンサイクルを用いた海洋温度差発電プラントの簡易動的モデルの構築
  • ランキンサイクル オ モチイタ カイヨウ オンドサ ハツデン プラント ノ カンイ ドウテキ モデル ノ コウチク

Search this article

Abstract

In this paper, a simple dynamic model for an OTEC plant using Rankine cycle is constructed. The proposed dynamic model consists of steady state calculation of state quantity based on mass balance and energy balance, and transient calculation of the heat exchanger dynamics. The proposed dynamic model can express both the steady state and the transient state of the OTEC plant. Moreover,evaluation indexes of the OTEC plant are obtained. Accuracy of the proposed dynamic model is evaluated by comparing with experimental results of an OTEC pilot plant.

Journal

Citations (1)*help

See more

References(6)*help

See more

Details 詳細情報について

Report a problem

Back to top