This paper shows that study of load ratio of mud-plastered walls and traditional construction frame, and attempt of the possibility of accumulation of strength of the elements. The specimens are composed of a traditional joints, and columns of alignment and number, Nuki of alignment, opening of height and width, and presence of Sashigamoi, etc. are different.<br>The following results were obtained. 1) Strength Load Ratio containing Nuki very early is around 30%. But, Strength Load Ratio will be reduced to 15% 100rad. Then gradually increased, reaching 40% 1/15rad. 2) The ratio of Strength Load of Frame of the opening with Mud walls, larger than the wall No the opening.The higher the proportion of the opening increases.