LONG-DURATION LOADING TEST ON LEAD DAMPERS CONSIDERING WIND LOAD
-
- TAKAOKA Eiji
- Building Construction Management Division, Kajima Corporation
-
- TAKENAKA Yasuo
- Architectural Design Division, Kajima Corporation
-
- KONDO Akihiro
- Architectural Design Division, Kajima Corporation
-
- HIKITA Makiko
- Kajima Technical Research Institute, Kajima Corporation
-
- IIBA Masanori
- Dept. of Structural Engineering, Building Research Institute
-
- OKUMA Takeshi
- Kanagawa Univ.
Bibliographic Information
- Other Title
-
- 風荷重を想定した鉛ダンパーの長時間加振実験
- カゼカジュウ オ ソウテイ シタ ナマリ ダンパー ノ チョウジカンカシンジッケン
Search this article
Abstract
To grasp the effects of creep and fatigue characteristics on lead dampers under wind load, long-duration cyclic loading tests were conducted. From the test results, the lateral restoring characteristics of the lead dampers in the small deformation range considering the creep characteristics were obtained. Although cracks were observed in the lead dampers with cyclic loading, they had little influence on the restoring characteristics including the yielding load of the lead dampers. Analytical results using a simplified estimation method considering the small deformation characteristics of lead dampers agreed well with the test results.
Journal
-
- AIJ Journal of Technology and Design
-
AIJ Journal of Technology and Design 18 (38), 55-60, 2012
Architectural Institute of Japan
- Tweet
Details 詳細情報について
-
- CRID
- 1390001205171361024
-
- NII Article ID
- 130004507268
-
- NII Book ID
- AN10531441
-
- ISSN
- 18818188
- 13419463
-
- NDL BIB ID
- 023523277
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed