INVESTIGATION ON INDOOR AIR QUALITY OF DETACHED HOUSES IN COLD CLIMATIC REGION OF JAPAN(Environmental Engineering)
-
- GENJO Kahori
- Dept. of Archi. & Env. Systems, Faculty of Systems Sci. & Tech., Akita Pref. Univ.
-
- MATSUMOTO Shin-ichi
- Dept. of Archi. & Env. Systems, Faculty of Systems Sci. & Tech., Akita Pref. Univ.
-
- HASEGAWA Ken-ichi
- Dept. of Archi. & Env. Systems, Faculty of Systems Sci. & Tech., Akita Pref. Univ.
-
- TANABE Shin-ichi
- Dept. of Arch., Waseda Univ.
Bibliographic Information
- Other Title
-
- 寒冷地の戸建住宅における室内空気質の実態調査(環境工学)
- 寒冷地の戸建住宅における室内空気質の実態調査
- カンレイチ ノ コダテ ジュウタク ニ オケル シツナイ クウキシツ ノ ジッタイ チョウサ
Search this article
Abstract
In order to clarify IAQ problem of detached houses located in cold climatic region, particularly well-insulated airtight houses, measurements were conducted in the winter since 2001. The formaldehyde concentrations in most houses were found to be lower than 100μg/m^3, but the TVOC concentrations in most houses including a conventional house that has low insulation and airtightness without mechanical ventilation system were higher than 400μg/m^3. Materials used in daily life as well as building materials might lead to emission of VOCs. It was suggested IAQ problem in cold climatic region would be serious in not only well-insulated houses but also ordinary houses.
Journal
-
- AIJ Journal of Technology and Design
-
AIJ Journal of Technology and Design 11 (21), 173-176, 2005
Architectural Institute of Japan
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390001205173330560
-
- NII Article ID
- 110006348625
-
- NII Book ID
- AN10531441
-
- ISSN
- 18818188
- 13419463
-
- NDL BIB ID
- 7391422
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed