DEVELOPMENT OF WOOD BRICK WALL STRUCTURES : Structural Behavior for Horizontal Loads

  • INOUE Masafumi
    Dept. of Architectural Engineering, Faculty of Engineering, Oita University
  • KINOSHITA Iwao
    Woody System Corporation
  • KIKUCHI Shigeaki
    Dept. of Architectural Engineering, Nishinippon Institute of Technology University
  • ETO Yoshinori
    Dept. of Architectural Engineering, Faculty of Engineering, Oita University
  • SHIMIZU Takeshi
    Dept. of Architectural Engineering, Faculty of Engineering, Oita University

Bibliographic Information

Other Title
  • 木製ブロック壁体を有する木質系住宅の開発 : 水平力に対する強度性能
  • 木製ブロック壁体を有する木質系住宅の開発 水平力に対する強度性能〔含 評論〕
  • モクセイ ブロック ヘキタイ オ ユウスル モクシツケイ ジュウタク ノ カイ

Search this article

Abstract

To investigate the structural behavior of wood brick wall structure, horizontal loading tests of wood brick wall with/ without opening were carried out. This structure has no column, beam and brace. This wood brick wall can resist both of the vertical and horizontal loads. The wood brick used in this structure is manufactured in the factory by using of dry wood same as the laminated heavy timber. Therefore, the configuration of this brick will never change. From horizontal loading tests results, horizontal strength is larger than that of walls used in the conventional wooden frame with brace.