Limitation of echocardiographic indexes for the accurate estimation of left ventricular relaxation and filling pressure: interim results of SMAP, a multicenter study in Japan
-
- YAMADA Satoshi
- Department of Cardiovascular Medicine, Hokkaido University Graduate School of Medicine
-
- IWANO Hiroyuki
- Department of Cardiovascular Medicine, Hokkaido University Graduate School of Medicine
-
- OHTE Nobuyuki
- Department of Cardio-Renal Medicine and Hypertension, Nagoya City University Graduate School of Medical Sciences
-
- SEO Yoshihiro
- Cardiovascular Division, Faculty of Medicine, University of Tsukuba
-
- YAMADA Hirotsugu
- Department of Cardiovascular Medicine, Tokushima University Hospital
-
- ISHIZU Tomoko
- Cardiovascular Division, Faculty of Medicine, University of Tsukuba
-
- KUSUNOSE Kenya
- Department of Cardiovascular Medicine, Tokushima University Hospital
-
- WAKAMI Kazuaki
- Department of Cardio-Renal Medicine and Hypertension, Nagoya City University Graduate School of Medical Sciences
-
- MIKAMI Taisei
- Faculty of Health Sciences, Hokkaido University
-
- TSUTSUI Hiroyuki
- Department of Cardiovascular Medicine, Hokkaido University Graduate School of Medicine
Bibliographic Information
- Other Title
-
- 心エコー図法による左室弛緩能と充満圧の評価の限界:多施設共同研究SMAPからの中間報告
Search this article
Description
Purpose: Mitral annular early-diastolic velocity (e´) and the early transmitral velocity to e´ ratio (E/e´) have been widely used as indexes of left ventricular (LV) relaxation and filling pressure, respectively. There are, however, a number of clinical settings in which e´ and E/e´ may not be reliable. We thus conducted a multicenter study in Japan (SMAP) to determine the accuracy of echocardiographic indexes of LV relaxation and filling pressure. Subjects and Methods: In 52 patients with various structural heart diseases from four institutions, time constant of LV pressure decay (τ) and LV mean diastolic pressure (LVMDP) were measured using a micromanometer-tipped catheter. Echocardiographic diastolic parameters were also measured. Results and Discussion: There was no difference in e´ between patients with and without abnormal relaxation. There was a weak, but significant, correlation between τ (48±11 msec) and e´ (r=-0.30, p=0.03), or deceleration time of pulmonary venous D wave (r=0.40, p=0.02). There was no difference in E/e´ between patients with and without elevated LV filling pressure. LVMDP (8.3±6.1 mmHg) significantly correlated with transmitral E/A (r=0.47, p=0.001), but not with E/e´ (r=0.27, p=0.053). Conclusion: The multicenter study in Japan demonstrated that e´ and E/e´ might be of limited use for estimating LV relaxation and filling pressure in patients with various structural heart diseases. Furthermore, e´ and E/e´ were not superior to the conventional indexes of LV inflow or pulmonary venous flow.
Journal
-
- Choonpa Igaku
-
Choonpa Igaku 39 (4), 449-456, 2012
The Japan Society of Ultrasonics in Medicine
- Tweet
Details 詳細情報について
-
- CRID
- 1390001205199417728
-
- NII Article ID
- 130004496860
- 10030811395
-
- NII Book ID
- AA11889584
-
- ISSN
- 18819311
- 13461176
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed