Abstract
In order to consider performance and method of performance evaluation to estimate primary energy consumption on domestic oil-fired heating boiler,an experiment on 3 types of combustion(vapourizing,rotary spraying,and pressure spraying combustion),was performed. The following result were obtained:1)The performance evaluation of boiler was found no relationship with using antifreeze,setting water temperature,ambient temperature of boiler,and combustion air temperature. 2)The boiler efficiency for load factor was in the range of 60 to 85%. 3)As a result of experiment,the equation to estimate boiler efficiency for load factor was made out.
Journal
-
- Journal of Environmental Engineering (Transactions of AIJ)
-
Journal of Environmental Engineering (Transactions of AIJ) 76 (662), 411-418, 2011
Architectural Institute of Japan
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390001205200273920
-
- NII Article ID
- 130004937007
-
- NII Book ID
- AA11830377
-
- ISSN
- 1881817X
- 13480685
-
- NDL BIB ID
- 11074194
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed