抄録

In this paper, the standards for residential energy efficiency of China were studied. Heat loss coefficient and annual heating load of appartment houses in China were calculated, the values of which were compared to that of Japan. The conclusions from this study are: Both the annual heating load and the heat loss coefficients in the Japanese standards are slightly larger than that in the Chinese standards; the standard on heat transfer coefficient in the Japanese standards is the strictest; the air exchange rate is between 0.5 and 1.0 for all these standards.