QUANTITATIVE EVALUATION OF MITIGATION EFFECT FOR THERMAL LOAD OF SOLAR RADIATION THROUGH THE GLASS WINDOW BY WALL GREENING
-
- TAKAYAMA Naru
- Postdoctoral Fellow, Dept. of Biological and Environmental Sciences, Faculty of Agriculture, Yamaguchi University, Dr. Agriculture
-
- YOSHIKOSHI Hisashi
- Postdoctoral Fellow, Dept. of Biological and Environmental Sciences, Faculty of Agriculture, Yamaguchi University, Dr. Agriculture
-
- YAMAMOTO Haruhiko
- Prof., Dept. of Biological and Environmental Sciences, Faculty of Agriculture, Yamaguchi University, Dr. Agriculture
-
- IWAYA Kiyoshi
- Postdoctoral Fellow, Dept. of Biological and Environmental Sciences, Faculty of Agriculture, Yamaguchi University, Dr. Agriculture
-
- HARADA Yoko
- The United Graduate School of Agricultural Sciences, Tottori University, M. Agriculture
-
- YAMASAKI Toshiaki
- The United Graduate School of Agricultural Sciences, Tottori University, M. Agriculture
-
- TATEISHI Yoshinari
- Graduate School of Agriculture, Yamaguchi University
Bibliographic Information
- Other Title
-
- 蔓植物を使った夏季の壁面緑化による日傘効果とガラス窓日射熱負荷軽減量の算定
- ツルショクブツ オ ツカッタ カキ ノ ヘキメン リョッカ ニ ヨル ヒガサ コウカ ト ガラス マド ニッシャ ネツフカ ケイゲンリョウ ノ サンテイ
Search this article
Description
In this study, the wall greening by vine with a simple net was constructed on the west side wall. For the purpose of quantitative evaluation for mitigation effect of thermal load by using wall greening, the model to estimate the solar radiation through the glass window was discussed. Estimated cumulative thermal load of solar radiation was corresponding to observed value. The mean error of transmissivity estimation every two hours from 9 AM to 5 PM was 0.90%, 0.89%, 2.02% and 3.17%, respectively. Our model tended to overestimate the sun-shading effect by wall greening from 3PM to 5PM in sparsity leaf condition of which the LAI was under 1.0. The relationship between the LAI of greening wall and the mean of solar radiation transmissivity through the window has a negative correlation. Each same time period, observed mean of solar radiation transmissivity through the window was reduced 4.40%, 4.15%, 6.53% and 10.13%, respectively with increase of LAI per unit.
Journal
-
- Journal of Environmental Engineering (Transactions of AIJ)
-
Journal of Environmental Engineering (Transactions of AIJ) 76 (661), 247-254, 2011
Architectural Institute of Japan
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390001205200739200
-
- NII Article ID
- 130004506273
-
- NII Book ID
- AA11830377
-
- ISSN
- 1881817X
- 13480685
-
- NDL BIB ID
- 11032434
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed