Application of a Near-Infrared Spectroscopic Technique to Estimate the Chloride Ion Content in Mortar Deteriorated by Chloride Attack and Carbonation

  • Kohri Masato
    Business headquarters, Fujita Construction Consultant Co., Ltd., Japan.
  • Ueda Takao
    Institute of Technology and Science, The University of Tokushima, Japan.
  • Mizuguchi Hiroyuki
    Institute of Technology and Science, The University of Tokushima, Japan.

抄録

A new inspection technique that uses near-infrared spectroscopy is focused on as a method for detecting the chloride ion content in concrete structures. The authors have been working to confirm the possibility of estimating comparatively easily the chloride content in concrete without chemical analysis and in a short time on site. In this study, mortar specimens deteriorated by the combination of chloride attack and carbonation were prepared for investigating the method of evaluating the chloride ion content in mortar with the near-infrared spectroscopic technique. As a result, it was found that the chloride ion content in a carbonated mortar specimen can be evaluated with a method similar to that used to detect deterioration due solely to chloride attack.

収録刊行物

被引用文献 (1)*注記

もっと見る

参考文献 (4)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ