- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Automatic Translation feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
The Effect of Powders and Transfer Sheets for Detecting of Latent Fingerprints on STR Typing
-
- Fujii Koji
- National Research Institute of Police Science
-
- Hibino Kazuhito
- National Police Agency
-
- Ito Motosada
- National Police Agency
-
- Inokuchi Shota
- National Research Institute of Police Science
-
- Kitayama Tetsushi
- National Research Institute of Police Science
-
- Nakahara Hiroaki
- National Research Institute of Police Science
-
- Mizuno Natsuko
- National Research Institute of Police Science
-
- Sekiguchi Kazumasa
- National Research Institute of Police Science
Bibliographic Information
- Other Title
-
- 指紋検出に用いる粉末および転写シートが STR 型検査に及ぼす影響
Search this article
Description
We examined whether powders and transfer sheets for detecting latent fingerprints affect DNA extraction and subsequent short tandem repeat (STR) typing adversely. To examine the powders, saliva and blood samples were smeared and dried on glass slides, and then adhered with aluminum powder, black powder, magnetic powder (NBS), magnetic powder (Sirche), SP black and indigo. To examine transfer sheets, saliva and blood samples were smeared and dried on gelatin sheets, JP sheet and Lifter. DNA was extracted from the powder-adhered samples or the samples on the sheets, quantified by a real-time PCR assay, and the STR typing was performed using the Identifiler kit.<br> The aluminum powder and the SP black affected the storage of the DNA solution, and required a centrifugation step to remove the powders, or required TE−4 buffer for DNA elution instead of water. The magnetic powder (NBS) made the DNA extraction impossible, when an excessive amount of the powder was adhered. However, the DNA extraction was possible, when most of the powder was removed with a magnetic brush. The black powder, the magnetic powder (Sirche) and the indigo gave enough DNA concentration and full STR profiles. All the transfer sheets did not give adverse effects.<br> As simulated casework samples, 20 fingerprints deposited on a glass slide in two different ways were enhanced with the aluminum powder and transferred to the gelatin sheets. DNA was extracted from the gelatin sheets, and the residual portion on the glass slide. The DNA concentration ≥0.01 ng/μl was obtained from 2 samples for the residual portion of 20 fingerprints deposited 2 hours after washing hands, and 7 samples for that of 20 samples deposited after touching forehead, cheeks and neck. The STR typing was performed from the samples ≥0.01 ng/μl. Full STR profiles were obtained from 6 samples (≥0.024 ng/μl) and partial STR profiles from 3 samples (0.10-0.12 ng/μl) when the residual portion used.<br>
Journal
-
- Japanese Journal of Forensic Science and Technology
-
Japanese Journal of Forensic Science and Technology 18 (2), 113-124, 2013
Japanese Association of Forensic Science and Technology
- Tweet
Details 詳細情報について
-
- CRID
- 1390001205247132928
-
- NII Article ID
- 130004485385
-
- ISSN
- 18814689
- 18801323
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed