REMOVAL OF ORGANICS AND NITROGEN IN ARTIFICIAL SEWAGE BY A COMBINED SYSTEM OF TWO-STEP UASB REACTOR AND AEROBIC BIOFILM REACTOR

Bibliographic Information

Other Title
  • 2槽式UASB-接触酸化処理システムにおける有機物と窒素の除去特性
  • 2ソウシキ UASB セッショク サンカ ショリ システム ニ オケル ユウキブツ ト チッソ ノ ジョキョ トクセイ

Search this article

Abstract

This study proposed a new sewage treatment system that combined a two-step UASB reactor (for removal of organics and denitrification) and an aerobic biofilm reactor. The laboratory-scale, combined system had been operated for 210 days by feeding a low-strength synthetic wastewater simulating domestic sewage. The combined system exhibited a very satisfactory performance in organics and nitrogen removal (achieving the removal rate of 91% and 61% respectively) at a HRT of only 4.7 h under the temperature range between 10 and 20°C with a circulation ratio of 2. Vial activity tests of retained sludge in the UASB reactor were conducted after the 210 days' operation.

Journal

Citations (1)*help

See more

References(37)*help

See more

Related Projects

See more

Details 詳細情報について

Report a problem