説明
The effects of diesel fuel split-injection on the fuel-air ratio and the gas velocity distribution inside the combustion chamber are numerically investigated using a modified KIVA-3V code that incorporates an Enhanced Taylor Analogy Breakup (ETAB) model into the calculation of spray droplet breakup. The second injection in the split-injection scheme can generate a sudden increase in the flammable mixture area inside the chamber. Among the schemes evaluated, the split-injection configuration in which 75% of the fuel mass is injected during the first injection and the remaining fuel mass is injected after a 1.0-ms dwell is preferred as the optimum configuration with respect to particulate emission reduction. The configuration tends to produce the widest flammable area inside the chamber during the mixing-controlled combustion phase. The dwell duration in split-injection schemes does not have a linear correlation with the area of the flammable mixture. The gas velocity distributions do not change significantly when the fuel injection mass ratio and dwell duration are varied.
収録刊行物
-
- Journal of Environment and Engineering
-
Journal of Environment and Engineering 3 (2), 316-325, 2008
一般社団法人 日本機械学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390001205262731136
-
- NII論文ID
- 130000077042
-
- ISSN
- 1880988X
-
- 本文言語コード
- en
-
- データソース種別
-
- JaLC
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可