Stress Distribution in a Cylinder and a Measurement-based Left Ventricular Shape Model

Bibliographic Information

Other Title
  • 実心臓に基づく形状及び円筒形状を用いた左心室拍動シミュレーションにおける収縮末期応力分布の比較
  • ジツ シンゾウ ニ モトズク ケイジョウ オヨビ エントウ ケイジョウ オ モチイタ サシンシツ ハクドウ シミュレーション ニ オケル シュウシュク マッキ オウリョク ブンプ ノ ヒカク

Search this article

Abstract

We evaluated the stress distribution in a cylindrical model and a shape model obtained from human heart using two different fiber orientations. For both orientation models, the results showed large differences between the stress distribution in the cylindrical model and the measurement-based shape model. These results suggest that stress distribution is highly dependent on the model geometry, and the usage of a measurement-based shape model is important for evaluating left ventricular (LV) wall stress distribution. This fact may have some influence on the reported homogeneity of stress distribution in an anatomical fiber orientation model that uses a mathematical symmetric shape model.

Journal

Citations (1)*help

See more

References(21)*help

See more

Related Projects

See more

Details 詳細情報について

Report a problem