Current status of unregulated volatile organic compounds (VOCs) in indoor air from elementary schools, japan
-
- MIZOUCHI Shigekazu
- Graduate School of Science and Engineering, Saga University
-
- ICHIBA Masayoshi
- Faculty of Medicine, Saga University
-
- MIYAJIMA Toru
- Graduate School of Science and Engineering, Saga University
-
- KODAMA Hiroki
- Analytical Research Center for Experimental Sciences, Saga University
-
- TAKAMUKU Toshiyuki
- Graduate School of Science and Engineering, Saga University
-
- SOMEYA Takashi
- Faculty of Agriculture, Saga University
-
- UENO Daisuke
- Faculty of Agriculture, Saga University
Bibliographic Information
- Other Title
-
- 小学校室内環境における未規制VOCs濃度の現状把握
- ショウガッコウ シツナイ カンキョウ ニ オケル ミキセイ VOCs ノウド ノ ゲンジョウ ハアク
Search this article
Description
Unregulated VOCs were determined in air samples collected from indoor environment of 70 classrooms in elementary schools, Japan (2011-2013). Unregulated VOCs were detected in all the samples analyzed in this study. 2-ethyl-1-hexanol (2E1H) was the predominant compound and its concentration range was 0.75-160μg/m3. 2E1H was followed by glycol ethers (GEs: nd-250μg/m3) and Texanols (nd-150μg/m3). This result suggests ubiquitous presences of these chemicals in school indoor environment. Significant higher concentrations of 2E1H were found in computer rooms than lecture rooms and science rooms (p< 0.05). However, GEs concentrations did not show significant differences among those rooms. Exposure assessment was conducted using the Lowest concentration of interest (LCI) and the highest concentrations detected in this study. As results of this assessment, hazard index (HI) showed less than 1. On the other hand, concentration ranges of 2E1H in this study was comparable to those for the threshold for allergic symptom in previous studies. Concentration ranges of GEs in this study was also comparable to those showed allergic symptom in Swedish epidemiologic research.
Journal
-
- Indoor Environment
-
Indoor Environment 17 (2), 69-79, 2014
Society of Indoor Environment, Japan
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390001205289554816
-
- NII Article ID
- 130004707682
-
- NII Book ID
- AA11443020
-
- ISSN
- 21864322
- 18820395
-
- NDL BIB ID
- 025945934
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed