環境リスク管理のための電位分布歪み法による漏水検知モニタリング網の設計

書誌事項

タイトル別名
  • Design of Leakage Detection Monitoring Networks for Environmental Risk Management by Electric Potential Distortion Method
  • カンキョウ リスク カンリ ノ タメ ノ デンイ ブンプ ヒズミホウ ニヨル

この論文をさがす

説明

Monitoring networks which will detect leachate leaks from landfill disposal sites need to be designed with an aim to better manage environmental risks traceable to these leaks. With regard to a system for detecting leaks in the case of a seepage control sheet break by monitoring electrical potential distortion, the authors needed to clarify the rate of leakage flow and important monitoring networks for the management of environmental risks caused by leakage. A model experiment and numerical simulation was made to quantitatively analyze the accuracy for measuring the size and location of the breaks. Based on the results, design requirements for leakage detection monitoring networks were made clear for the management of environmental risks.