ストーカ式ごみ焼却炉におけるごみ供給量安定化システムの開発研究

書誌事項

タイトル別名
  • Developmental Study of MSW Feed Rate Stabilization System for Stoker-Type MSW Incinerators
  • ストーカシキゴミ ショウキャクロ ニ オケル ゴミ キョウキュウリョウ アンテイカ システム ノ カイハツ ケンキュウ ゴミ ノ テイイ ハツネツリョウ スイテイ アツミツトクセイ ニ カカワル キソ ケンキュウ
  • —Lower Heating Value Presumption and Compaction Characteristic of MSW—
  • ―ごみの低位発熱量推定, 圧密特性に係る基礎研究―

この論文をさがす

抄録

The relationship between the bulky density of MSW and its lower heating value was clarified as part of research for the establishment of the MSW feed rate stabilization system in stoker-type MSW incinerator. The compaction characteristic of MSW was also examined through experimentation with artificial MSW.<BR>A strong correlation was admitted to exist between bulky density and the lower heating value of MSW. The presumption of the lower heating value became possible by measuring bulky density, although population and regional difference played an influential role in the bulky density concept.<BR>There was great volume change for MSW in the feed part, and this became crucial when considering the compaction of MSW for the presumption of the MSW feed rate. The compaction characteristic curve obtained by the experiment consisted of the part expressed in the second approximation evaluation and in the first approximation equation. Though the curves depended on the composition of the MSW and/or the compaction experimental method, their shapes were basically similar.